Advanced cooling and power supply technologies can effectively solve the air conditioning cooling problem of high-density racks, improve the operational efficiency of internal equipment in data centers, reduce PUE values, and greatly promote the green process of data center construction.
Installation method: factory prefabricated modular components, quick on-site installation and deployment, productization and standardization of equipment in the computer room.
Integrated components: cabinets, UPS, air conditioning, distribution cabinets, intelligent monitoring, etc.
Intelligent monitoring: It can monitor voltage, current, power, temperature and humidity, PUE and other data, and provide historical data query.
Classification of closed aisle forms: closed hot aisle or closed cold aisle, closed cold aisle adopts skylight+end door system to close cold aisle; The closed hot aisle adopts a vertical airflow partition and end door system to seal the hot aisle. Optimize airflow organization, isolate cold and hot airflows, greatly reducing air conditioning energy consumption.
Applicable scenarios:
IDC, Communication rooms, data centers for various industries (government, finance, education, healthcare, transportation), and enterprise data centers.
In summary, ZTT micro modular data center is a complete and small data center that can be independently used for computing or storage resources. It adopts factory prefabricated modular components and unified interface standards to achieve fast and flexible deployment of data centers, significantly reducing construction costs and shortening deployment cycles.
Solution 1: Place the air conditioning outside
Suitable for green and energy-saving data centers with long channels, low load on single cabinets, and high room space.
Solution 2: Place the battery outside
Suitable for green and energy-saving data centers with a small number of cabinets, high load on individual cabinets, and limited floor height in the data center.
Solution 3: Place the battery inside
Suitable for green and energy-saving data centers with limited space in the computer room and inability to expand the power battery room.
Solution 4: DPS power supply
Suitable for green and energy-saving data centers with limited room space, inability to expand power batteries, and flexible phased expansion needs.
Micro modular data center | ||
Category | Item | Technical parameter |
Overall performance | Single cabinet size (length * width * height) | L*2400mm*2000mm/2200mm(L ≤15m) |
Dual cabinet size (length * width * height) | L*3600mm*2000mm/2200mm(L ≤ 15m) | |
Reliability level | Tier l or above | |
Working environment temperature | -30℃~ 45℃ | |
Working environment humidity | 5% ~ 95% | |
Altitude | ≤ 1000m, the excess part shall be downgraded according to relevant standards for use | |
Installation method | Support both ground installation and base installation methods | |
Cabinet system | Size specifications | 300/600mm*1200mm*2000/2200mm |
Available space | 42U-56U | |
Perforated rate of door | ≥ 75% | |
Dynamic bearing | ≥ 1200KG | |
Static bearing | ≥ 1500KG | |
Seismic grade | Level 8,9 | |
Protection level | IP20 | |
Others | Optional accessories: tray, blind plate, PDU, grounding copper bar, pulley, etc | |
Closed aisle | Skylight | width 300/600mm flip skylight or fixed skylight or functional skylight |
Door | Sliding doors, swing doors | |
Access control | Supports identification methods such as passwords, IC cards, fingerprints, etc | |
Cable tray | Network cable tray/M-shaped sheet metal cable tray/aluminum profile cable tray/fiber optic channel | |
Base | Cabinet base, aisle base | |
Anti static floor | Calcium sulfate anti-static floor | |
Lighting | LED energy-saving lamp, optional ambient light | |
UPS system | Input rated voltage | 380/400/415Vac,3P+N+E,50/60HZ |
Input power factor | >0.99 (full load) | |
Output power factor | 0.9 | |
Rated capacity | 20-300KVA (supports online expansion) | |
Communication interface | RS232、RS485、SNMP、 Dry contact, EPO interface, Generator interface | |
Operation mode | Online modular UPS (supporting online hot swappable maintenance) | |
Distribution system | input voltage | 380/400/415Vac,3P+N+E,50/60HZ |
Rated capacity | DC: 100A-1250A, AC: 100A-630A | |
Input method | Single/Dual Route | |
Output circuit | Standard 21-126P | |
Intelligent monitoring | Provide power supply for AC or DC loads, with functions such as distribution, monitoring, measurement, protection, and alarm | |
Air conditioning system | Dimension | 300/600mm*1200mm*2000/2200mm |
Cooling capacity | 25KW ~ 40KW | |
Cooling method | Air cooling/Water cooling | |
Air volume | 4000 ~ 7700m3 | |
Monitoring system | Environmental monitoring | Temperature and humidity, smoke detector, water leakage, access control, camera |
Power equipment monitoring | Power supply, battery, power distribution, air conditioning | |
Alarm method | Sound and light alarm, voice alarm, mobile phone SMS alarm, email alarm |