Micro modular data center
A Leading Global Manufacturer of Cable Systems

Zhongtian Broadband Technology Co., Ltd. provides data center products and solutions of different scales according to customer needs, including edge data centers, small and medium-sized data centers, and large data centers, with the ability to integrate products, solutions, and deliver integrated solutions.

Design & Construction

Advanced cooling and power supply technologies can effectively solve the air conditioning cooling problem of high-density racks, improve the operational efficiency of internal equipment in data centers, reduce PUE values, and greatly promote the green process of data center construction.

Installation method: factory prefabricated modular components, quick on-site installation and deployment, productization and standardization of equipment in the computer room.

Integrated components: cabinets, UPS, air conditioning, distribution cabinets, intelligent monitoring, etc.

Intelligent monitoring: It can monitor voltage, current, power, temperature and humidity, PUE and other data, and provide historical data query.

Classification of closed aisle forms: closed hot aisle or closed cold aisle, closed cold aisle adopts skylight+end door system to close cold aisle; The closed hot aisle adopts a vertical airflow partition and end door system to seal the hot aisle. Optimize airflow organization, isolate cold and hot airflows, greatly reducing air conditioning energy consumption.


Applicable scenarios:

IDC, Communication rooms, data centers for various industries (government, finance, education, healthcare, transportation), and enterprise data centers.

In summary, ZTT micro modular data center is a complete and small data center that can be independently used for computing or storage resources. It adopts factory prefabricated modular components and unified interface standards to achieve fast and flexible deployment of data centers, significantly reducing construction costs and shortening deployment cycles.


Solution 1: Place the air conditioning outside

Suitable for green and energy-saving data centers with long channels, low load on single cabinets, and high room space.


Solution 2: Place the battery outside

Suitable for green and energy-saving data centers with a small number of cabinets, high load on individual cabinets, and limited floor height in the data center.


Solution 3: Place the battery inside

Suitable for green and energy-saving data centers with limited space in the computer room and inability to expand the power battery room.


Solution 4: DPS power supply

Suitable for green and energy-saving data centers with limited room space, inability to expand power batteries, and flexible phased expansion needs.


Micro modular data center

Category

Item

Technical parameter

Overall performance

Single cabinet size (length * width * height)

L*2400mm*2000mm/2200mmL ≤15m


Dual cabinet size (length * width * height)

L*3600mm*2000mm/2200mmL ≤ 15m


Reliability level

Tier l or above


Working environment temperature

-30℃45℃


Working environment humidity

5% 95%


Altitude

≤ 1000m, the excess part shall be downgraded according to relevant standards for use


Installation method

Support both ground installation and base installation methods

Cabinet system

Size specifications

300/600mm*1200mm*2000/2200mm


Available space

42U-56U


Perforated rate of door

≥ 75%


Dynamic bearing

≥ 1200KG


Static bearing

≥ 1500KG


Seismic grade

Level 89


Protection level

IP20


Others

Optional accessories: tray, blind plate, PDU, grounding copper bar, pulley, etc

Closed aisle

Skylight

width 300/600mm  flip skylight or fixed skylight or functional skylight


Door

Sliding doors, swing doors


Access control

Supports identification methods such as passwords, IC cards, fingerprints, etc


Cable tray

Network cable tray/M-shaped sheet metal cable tray/aluminum profile cable tray/fiber optic channel


Base

Cabinet base, aisle base


Anti static floor

Calcium sulfate anti-static floor


Lighting

LED energy-saving lamp, optional ambient light

UPS system

Input rated voltage

380/400/415Vac3P+N+E50/60HZ


Input power factor

>0.99 (full load)


Output power factor

0.9


Rated capacity

20-300KVA (supports online expansion)


Communication interface

RS232RS485SNMPDry contact, EPO interface, Generator interface


Operation mode

Online modular UPS (supporting online hot swappable maintenance)

Distribution system

input voltage

380/400/415Vac3P+N+E50/60HZ


Rated capacity

DC: 100A-1250A, AC: 100A-630A


Input method

Single/Dual Route


Output circuit

Standard 21-126P


Intelligent monitoring

Provide power supply for AC or DC loads, with functions such as distribution, monitoring, measurement, protection, and alarm

Air conditioning system

Dimension

300/600mm*1200mm*2000/2200mm


Cooling capacity

25KW 40KW


Cooling method

Air cooling/Water cooling


Air volume

4000 7700m3

Monitoring system

Environmental monitoring

Temperature and humidity, smoke detector, water leakage, access control, camera


Power equipment monitoring

Power supply, battery, power distribution, air conditioning


Alarm method

Sound and light alarm, voice alarm, mobile phone SMS alarm, email alarm